Confirm the neurostimulation system is functioning correctly after the procedure. Surgical complications include, but are not limited to, the following: intracranial hemorrhage (which can lead to stroke, paralysis, or death); cerebrospinal fluid leakage or cerebrospinal fluid abnormality; persistent pain at surgery site or IPG site; brachial plexus injury (nerves to chest, shoulder and arm); postoperative pain, stress, or discomfort; hemiparesis (muscular weakness or partial paralysis on one side of body); ballism or hemiballism (uncontrollable movements on both or only one side of the body); confusiontransient, nocturnal or ongoing; cognitive impairment, including delirium, dementia, disorientation, psychosis and speech difficulties; pulmonary embolism (sudden blood vessel obstruction); aborted procedures (air embolism, unable to find target, surgical complication, etc. Poor surgical risks. Do not use the system if the use-before date has expired. Before using an electrosurgery device, place the device in Surgery Mode using the patient controller app or clinician programmer app. Excessive heat, excessive traction, excessive bending, excessive twisting, or the use of sharp instruments may damage and cause failure of the components. Electrical pulses from a neurostimulation system may interact with the sensing operation of an implanted cardiac system, causing the cardiac system to respond inappropriately. The following additional considerations should be made for patients with diabetes: A pre-operative risk assessment should be performed for patients with diabetes who are at high risk for ischemic heart disease, those with autonomic neuropathy or renal failure, and patients with a Hemoglobin A1C (HbA1c) 8% (64 mmol/mol). Sources of therapeutic radiation include therapeutic X-rays, cobalt machines, and linear accelerators. Why Proclaim XR SCS System - Abbott Neuromodulation | For Consumers | Abbott U.S. During the implant procedure, if an electrosurgery device must be used, take the following actions:. Unilateral or bilateral stimulation of the thalamus, internal globus pallidus (GPi), or subthalamic nucleus (STN) in patients with levodopa-responsive Parkinsons disease. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions. For less than 30 m (100 ft) of water or pressures below 4.0 ATA, durations of less than 60 minutes are recommended. The following precautions apply to this neurostimulation system. Excessive heat, excessive traction, excessive bending, excessive twisting, or the use of sharp instruments may damage and cause failure of the components. Needle positioning. Patient's visual ability to read the patient controller screen. Application modification. Keep them dry to avoid damage. Patients using therapy that generates paresthesia should turn off stimulation before operating motorized vehicles, such as automobiles, or potentially dangerous machinery and equipment because sudden stimulation changes may distract them from properly operating it. In the clinical experience with this device, patients have experienced few effects when moving from lying down to sitting up. Instruct patients to designate a representative (family member or close friend) to notify any emergency medical personnel of their implanted neurostimulation system if emergency care is required. Important note: For CT procedures that require scanning over the medical device continuously for more than a few seconds, as with CT perfusion or interventional exams, attending staff should be ready to take emergency measures to treat adverse reactions if they occur. This neurostimulation system is indicated as an aid in the management of chronic, intractable pain of the trunk and/or limbs, including unilateral or bilateral pain associated with the following: failed back surgery syndrome and intractable low back and leg pain. To prevent unintended stimulation, do not modify the operating system in any way. The use of ultrasonic scanning equipment may cause mechanical damage to an implanted neurostimulation system if used directly over the implanted system. If they must go through a gate or doorway containing this type of device, patients should turn off their IPG and proceed with caution, being sure to move through the device quickly. The long-term safety associated with multiple implants, leads left in place without use, replacement of leads, multiple implants into the target structure, and lead explant is unknown. Before diving or using a hyperbaric chamber, patients should discuss the effects of high pressure with their physician. Unilateral or bilateral stimulation of the internal globus pallidus (GPi) or the subthalamic nucleus (STN) for the management of intractable, chronic dystonia, including primary and secondary dystonia, for patients who are at least 7 years old. Proclaim Plus Spinal Column Stimulation (SCS) System PRESCRIPTION AND SAFETY INFORMATION Read this section to gather important prescription and safety information. Anchoring leads. This includes oxygen-enriched environments such as hyperbaric chambers. Conscious sedation during removal. Coagulopathies. Pressures below 30 m (100 ft) of water (or above 4.0 ATA) could damage the neurostimulation system. The use of components not approved for use by Abbott Medical with this system may result in damage to the system and increased risk to the patient. Application modification. Remove the stylet from the lead only when satisfied with lead placement. Unauthorized changes to stimulation parameters. After defibrillation, confirm the neurostimulation system is still working. away from the generator and avoid placing any smart device in a pocket near the generator. Advise patients to inform their healthcare professional that they should not be exposed to diathermy treatment. Physicians should also discuss any risks of MRI with patients. Abbott Launches the World's Smallest Implantable, Rechargeable Spinal The patient should be able and willing to use the patient controller and correctly interpret the icons and messages that appear on the screen. Extension of the upper torso or neck may cause lead movement and alter the stimulation field (especially with leads in the cervical area), resulting in overstimulation or ineffective stimulation. away from the generator and avoid placing any smart device in a pocket near the generator. Wireless use restrictions. Do not use a clinician programmer or patient controller around explosive or flammable gas fumes or vapors. The Proclaim XR SCS system can provide relief to . Patients should avoid getting too close to these types of EMI sources, which include the following examples: commercial electrical equipment (such as arc welders and induction furnaces), communication equipment (such as microwave transmitters and high-power amateur transmitters), high-voltage power lines, radiofrequency identification (RFID) devices, and some medical procedures (such as therapeutic radiation and electromagnetic lithotripsy). Radiofrequency or microwave ablation. Infections related to system implantation might require that the device be explanted. All components listed must be implanted unless noted as "optional." ); complications from unusual physiological variations in patients, including foreign body rejection phenomena; paralysis (loss of motor function, inability to move); Possible deep brain stimulation complications. Using surgical instruments. This neurostimulation system is designed to deliver low-intensity electrical impulses to nerve structures. Removing components. Neurostimulation should not be used on patients who are poor surgical risks or patients with multiple illnesses or active general infections. Patients should cautiously approach such devices and should request help to bypass them. Securing the anchor. Additionally, RFID devices, which are often used to read identification badges, as well as some tag deactivation devices, such as those used at payment counters at stores and loan desks at libraries, may also affect stimulation. Advance the needle and guidewire slowly. Additional Disadvantages. The placement of the leads involves some risk, as with any surgical procedure. This neurostimulation system is indicated as an aid in the management of chronic, intractable pain of the trunk and/or limbs, including unilateral or bilateral pain associated with the following: failed back surgery syndrome, intractable low back and leg pain, and diabetic peripheral neuropathy of the lower extremities. Always perform removal of implanted components with the patient conscious and able to give feedback. The equipment is not serviceable by the customer. Some equipment in home, work, medical, and public environments can generate EMI that is strong enough to interfere with the operation of a neurostimulation system or damage system components. The safety and effectiveness of neurostimulation for pediatric use have not been established. If you are unsure of the policy that applies to the use of this device, please ask for authorization to use it before turning it on. Abbott's Proclaim XR Spinal Cord Stimulation System Now Offers Expanded MRI Compatibility in U.S. - New U.S. FDA-approved labeling lifts restrictions on 60-centimeter Octrode leads,. A physician can help determine if a patient is eligible to receive an MRI scan by following the requirements provided by Abbott Medical. Patients should be advised to avoid carrying mobile phones in their shirt pocket or otherwise placing them directly over the deep brain stimulation system components. Keep programmers and controllers dry. Detailed information on storage environment is provided in the appendix of this manual. **Please note that in 1994, a consensus group of pain medicine experts gathered by the International Association for the Study of Pain (IASP) reviewed diagnostic criteria and agreed to rename reflex sympathetic dystrophy (RSD) and causalgia as complex regional pain syndrome (CRPS) types I and II, respectively. Clinician training. Approved models and implant locations for an MR Conditional lead-only system. Safety Info ID# Safety Topic / Subject Article Text 294: Spinal Cord Stimulation Systems: St. Jude Medical: Genesis, GenesisXP, GenesisRC, Eon, Eon C, Eon Mini, and Renew The Genesis, GenesisXP, GenesisRC, Eon, EonC, Eon Mini, and Renew neuromodulation devices (St. Jude Medical) used for spinal cord stimul. Equipment is not serviceable by the customer. Consumer goods and electronic devices. Magnetic resonance imaging (MRI). Patients will receive an identification card to carry with them that will inform emergency medical personnel of their implanted system. Some patients may be implanted with the components that make up a Magnetic Resonance (MR) Conditional system, which allows them to receive an MRI scan if all the requirements for the implanted components and for scanning are met. Sheath retraction. Other active implantable devices. Instruct patients to use their neurostimulation system only after an authorized clinician has programmed the device and has trained the patient how to control stimulation and safely use the system. Physicians should use extreme care with lead implantation in patients with a heightened risk of intracranial hemorrhage. Patients should avoid getting too close to these types of EMI sources, which include the following examples: commercial electrical equipment (such as arc welders and induction furnaces), communication equipment (such as microwave transmitters and high-power amateur transmitters), high-voltage power lines, radiofrequency identification (RFID) devices, and some medical procedures (such as therapeutic radiation and electromagnetic lithotripsy). Operation of machines, equipment, and vehicles. Additionally, RFID devices, which are often used to read identification badges, as well as some tag deactivation devices, such as those used at payment counters at stores and loan desks at libraries, may also affect stimulation. Store components and their packaging where they will not come in contact with liquids of any kind. INTENDED USE This neurostimulation system is designed to deliver low-intensity electrical impulses to nerve structures. It's small, discreet and available with Abbott's proprietary BurstDR stimulation, a new technology that's clinically proven to . When multiple leads are implanted, route the lead extensions so the area between them is minimized. Advise patients about adverse effects. Activities requiring excessive twisting or stretching. If needed, return the equipment to Abbott Medical for service. Patients should exercise reasonable caution when participating in activities that require coordination, including those that they were able to perform prior to receiving DBS therapy (for example, swimming). The safety and efficacy for the treatment of patients who have back pain as the greatest region of pain have not been evaluated. Do not crush, puncture, or burn these devices because explosion or fire may result. If you are unsure of the policy that applies to the use of this device, please ask for authorization to use it before turning it on. Patients who are unable to properly operate the system. Use extreme care to not damage the lead with the sharp point of the tunneling tool. Regardless if the device is deactivated, take care to monitor the device for proper function during and after treatment. Allow only authorized use of the clinician programmer to avoid any programming changes that may injure a patient. Patients should not be dependent on drugs and should be able to operate the neurostimulation system. For more information about MR Conditional deep brain stimulation (DBS) components and systems, including equipment settings, scanning procedures, and a complete listing of conditionally approved components, refer to the MRI procedures clinician's manual for DBS systems(available online atmedical.abbott/manuals). Removing a kinked sheath. If two systems are implanted, ensure that at least 20 cm (8 in.) Magnetic resonance imaging (MRI). For complete guidance, directions, and cautions on MRI safety with a specific device, please review the MRI procedure clinician's manual. Additional risks to the patients, as a result of the placement and stimulation of the lead in the area of the dorsal root ganglion (DRG), include pain from setting the stimulation parameters too high. IPGs contain batteries as well as other potentially hazardous materials. All components listed must be implanted unless noted as "optional." A summary of the safety and clinical performance (SSCP) for these devices will be published at https://ec.europa.eu/tools/eudamed by the Notified Bodies in accordance with the requirements of EU MDR 2017/745 and associated timelines. Lead inspection. Securing the lead with the lead stabilizer will mitigate this risk. Use caution when securing the soft tissue anchor because damage to the anchor or lead can occur and result in failure of the system. Schu S, Gulve A, ElDabe S, et al. Operation of machines, equipment, and vehicles. Component manipulation. 74372 MAT-2215216 v3.0 | Item approved for U.S. use only. Deep brain stimulation complications include, but are not limited to, the following: Undesirable changes in stimulation related to cellular changes in tissue around the electrodes, changes in the electrode position, loose electrical connections, or lead fracture, Loss of therapeutic benefit as a result of change in electrode positions, loose electrical connections, or lead or extension fracture, Initial jolt or tingling during stimulation; jolting or shocking sensations, Lead fracture, migration, or dislodgement, Extension malfunction, fracture, or disconnect, Deep brain stimulation system failure or battery failure within the device, Deep brain stimulation system malfunction or dislodgement, Allergic or rejection response to implanted materials, Persistent pain, tightness, or redness at the incision sites or general pain, General erosion or local skin erosion over the IPG, Persistent pain, tightness, or discomfort around the implanted parts (e.g., along the extension path in the neck), Impaired wound healing (e.g., incision site drainage) or abscess formation, Additional neurosurgical procedure to manage one of the above complications or to replace a malfunctioning component, Stimulation-related complications or other complications, Worsening of motor impairment and Parkinsons disease symptoms including dyskinesia, rigidity, akinesia or bradykinesia, myoclonus, motor fluctuations, abnormal gait or incoordination, ataxia, tremor, and dysphasia, Paresis, asthenia, hemiplegia, or hemiparesis, Sensory disturbance or impairment including neuropathy, neuralgia, sensory deficit, headache, and hearing and visual disturbance, Speech or language impairment including, aphasia, dysphagia, dysarthria, and hypophonia, Cognitive impairment including attention deficit, confusion, disorientation, abnormal thinking, hallucinations, amnesia, delusions, dementia, inability to act or make decisions, psychic akinesia, long term memory impairment, psychiatric disturbances, depression, irritability or fatigue, mania or hypomania, psychosis, aggression, emotional lability, sleep disturbance, anxiety, apathy, drowsiness, alteration of mentation, postural instability and disequilibrium, Cardiac dysfunction (e.g., hypotension, heart rate changes, or syncope), Eye disorder including eye apraxia or blepharospasm, (1) The symbol statement Rx only or only or the statement Caution: Federal law restricts this device to sale by or on the order of a ___, the blank to be filled with the word physician, dentist, veterinarian, or with the descriptive designation of any other practitioner licensed by the law of the State in which the practitioner practices to use or order the use of the device; and. Battery care. In some cases, symptoms may return with a greater intensity than what a patient experienced before system implantation (rebound effect). Explosive and flammable gasses. Patients should cautiously approach such devices and should request help to bypass them. Spinal cord stimulation of the dorsal root ganglion for groin pain-a retrospective review. If stimulation is not turned off, the patient may experience a momentary increase in stimulation, which may be uncomfortable. Infections related to system implantation might require that the device be explanted. Use extreme care when handling system components. Do not bring the suture needle in contact with an IPG, lead, or extension, or the component may be damaged. Too much pressure on the stylet could damage the lead, resulting in intermittent or loss of stimulation. Implantation at vertebral levels above T10. Return all explanted IPGs to Abbott Medical for safe disposal. Do not handle the generator if the case is pierced or ruptured because severe burns could result from exposure to battery chemicals. Instructions for Use Website - SJM Our Invisible Trial System TM is a discreet, app . The Prodigy MRI SCS System delivers effective pain relief through spinal cord stimulation (SCS) using Abbott's smallest implantable pulse generator (IPG). Damage to the lead body can cause improper function and stimulation or stimulation to areas other than the intended target. Low frequencies. Ensure the neurostimulator is off before initiating an electrocardiogram (ECG).